Power Plant Boiler Air Velocity and Volume On-line Monitor System

Free-maintenance for 8 years, more than 200 successful applications.

After long-term research and practice of the performance of gas-solid two-phase flow, Luculent developed the power plant boiler air velocity and volume on-line monitor system ------Luculent intelligent Flow Transducer series, completely solve technical problems of easily plug, easily wear, low precision, high pressure loss etc, so that key parameters in boiler combustion can be effectively and real-timely monitored, and operation adjustment and fault diagnosis are evidence-based.

Performance & Specifications :


Technical Difference Table :

Comparative Item

Luculent LiFE

Airfoil-Type

Thermal-conductivity Type

Velocity-Averaging Tube Type (Barie)

Installation

Plug-in Installation

Tube-crossed Installation

Plug-in Installation

Plug-in Installation

Anti-blocking

Self-ash-clearing device, Anti-blocking type of essence

The pressure tapping is easy to be blocked as long-term running for the dusted measurement condition.

The sensor is easy to stick impurities as long-term running for the dusted measurement condition.

The pressure tapping is easy to be blocked as long-term running for the dusted measurement condition.

Pressure Loss

small

big

small

small

Straight Pipe Section

Multi-point measuring method, low requirement to the straight pipe section.

High requirement to the straight pipe section.

High requirement to the straight pipe section.

High requirement to the straight pipe section.

Maintenance

Free maintenance for long-term running

Need back flushing once blocking, need much maintenance.

Need to clear the ash for the sensor periodically.

Need back flushing once blocking, need much maintenance.

Specifications:

The LiFE series products solve wearing problem by using special material, and solve the blocking problem by using the self-ash clearing mechanism with special design, and settle the low-precision problem by using uniform cross multi-point measuring technology, realize on-line real-time measuring the primary and secondary air speed and flow for the boiler of power station, provide the basis of boiler combustion adjustment for the operator, and raise the combustion efficiency of the boiler.

1.Air-powder Tube Air Speed Measurement Device:

Apply to air speed measurement of air-powder tube, may be installed before or behind the powder tube below the Storage Type Coal Pulverizing System, or at the exit of Pulverizer of direct firing pulverizing system.
The Air-powder Tube Air Speed Measurement system is that install the LUSE back-leaned air speed sensor with precise set in the air pipe, the difference between the total pressure at the front end of the sensor and the static pressure at the back end of the sensor is transmitted to the Differential Pressure Transmitter, output the dynamic pressure signal, then it is processed by parameter compensation and calculation, gain the value of the air speed at last.


3. Air Speed Measurement Device for the nozzle of the secondary air.
Apply to the Air Speed Measurement for the nozzle of the secondary air.
For the measurement of the air speed at the nozzle of the secondary air, the measurement point is near to the chamber nozzle, it exists turbulent flow in the air duct, it can’t reflect the flow distribution condition in the air duct precisely if only using one measurement point, so should adopt the technology of multi-point measurement device and air-duct uniform area, to measure air pressure value for each region, then carry out averaging pressure process, so that obtain the whole air duct’s pressure signal and air speed precisely.